On each stud this makes a total of 3 o c.
Do i need to shear wall for siding.
I m set in my ways.
Is t 111 siding considered structural.
And stagger nails 6 o c.
Framing or one bay for 24 inch o c.
The walls of your home are an environmental separator.
Even if you never have a storm or an earthquake or otherwise any need for the shear stregnth of your exterior walls somewhere sometime someone s gonna throw a baseball at your garage and it s gonna punch a nice hole in your nice hardi siding.
For walls longer than 12 feet you ll need to butt additional lengths of siding together.
Siding shear walls 2306 3 wood structural panel shear walls.
A wall with doors and windows may require less squares of material to cover than a wall with no doors.
Nailing on this edge or nail into the.
2 on the ends if there is a double stud for a hold down you can either stitch nail the two studs together 3 o c.
Remove and repair any damage portions and use a weather restrictive barrier between our product and the preexisting siding.
The building envelope to do their jobs without being assaulted by wind precipitation and uv rays.
For example an average door is 3ft wide by 7ft.
You can go over preexisting siding as long as it is flat and in good shape.
The taller it is the more of a tendency it has to turn over when a lateral force is applied.
Right but to make it into shear i d have to nail the sh t out of it with big headed nails rather than the slight head spirals that i use with t1 11.
Butt joints in adjacent courses should be spaced apart by at least two stud bays for 16 inch o c.
Their job is to keep the inside in and the outside out.
This guide is available as a free download from the apa.
Need to combine with top floor hold down requirements based on capacity of first shear wall panel does not include dead load.
I want to frame sheathe a wall with cdx install felt and windows and doors and then install siding or preferably sidewall shingles.
Remember your shear wall may be the only thing between safety and catastrophe and it needs to be built perfectly.
Finally as for shear stregnth i can rip a hardi panel w my bare hands.
It s best to stagger the joints in each successive course to avoid noticeable patterns.
The.
You need increase the fastener length the thickness of the siding and make sure the fasteners go into the framing.
In order to be effective tall skinny shearwalls either need to grow in width or the connections between the sheathing and framing members need to be increased.